5.4.3 Study of Odor Preconcentrator Using SAW Device

Event
14th International Meeting on Chemical Sensors - IMCS 2012
2012-05-20 - 2012-05-23
Nürnberg/Nuremberg, Germany
Chapter
5.4 Resonant Sensors II
Author(s)
Y. Yokoshiki, T. Kakamoto - Department of Physical Electronics, Graduate School of Science and Engineering, Tokyo Institute of Technology (Japan)
Pages
477 - 480
DOI
10.5162/IMCS2012/5.4.3
ISBN
978-3-9813484-2-2
Price
free

Abstract

A new type preconcentrator was realized by using a SAW device and peltier devices. First, the odor is delivered to preconcentrator, in which the peltier device cools the surface of SAW device to accumulate the odor. Then the odor is atomized by acoustic streaming using the SAW device. As a result, we obtained much higher response to 1- nonanol, one of low-volatile compounds, because of preconcentrator effect.