Banner

MP73 - Optimization of Ultrasound Coupling for Clamp-On Flowmeters Using FEM Tools

Event
EUROSENSORS XXXVII
2025-09-07 - 2025-09-10
Wroclaw
Band
Poster I
Chapter
Theory, Modelling, Design and Testing
Author(s)
M. Schackmar, A. Bittner, A. Dehé, P. Selle, A. Sikora - Hahn-Schickard-Gesellschaft für angewandte Forschung e.V., Villingen-Schwenningen (Germany), T. Engel, T. Hahn-Jose - inoson GmbH, St. Ingbert (Germany)
Pages
349 - 350
DOI
10.5162/EUROSENSORS2025/MP73
ISBN
978-3-910600-07-2
Price
free

Abstract

Many state-of-the-art flowmeters are based on ultrasonic time-of-flight measurements. To enable an easy, fast and low-cost clamp-on mounting with an appropriate signal level, the materials and geometries must be tailored accord-ingly. Within this study, various materials for coupling wedges and matching-layers were evaluated with respect to acoustic impedance and transmission performance using the finite element method (FEM). Additionally, the inci-dence angle between the transducer and the fluid interface was optimized to maximize energy transfer and to minimize reflections. The simulation results were then compared with experimental measurements, showing im-proved signal quality and consistency across different setups. In future work these highly accurate measurements will be used for an AI-based leakage detection.

Download