Abstract
This study investigates acoustic focusing using a PDMS convex lens. The results revealed that the lens caused a shift in the focal region towards the transducer, as observed in experiments and simulations. The lens reduced near-field interference, increased output pressure, and improved beam convergence as indicated by a narrower beam profile. These findings highlight the potential of PDMS lenses for optimizing the performance of ultrasound transducers, including micromachined ultrasound transducers (MUTs), for various applications.