Banner

C6-b3 - A Holo-array for Enhancement of Ultrasonic Focusing

Event
2025 ICU PADERBORN - 9th International Congress on Ultrasonics
2025-09-21 - 2025-09-25
Paderborn
Band
Lectures
Chapter
C6-a - Guided Waves and Their Applications in NDT and SHM
Author(s)
Y. Lang, Z. Yang, X. Chen - Xi’an Jiaotong University, Xian (China), Z. Su - The Hong Kong Polytechnic University, Hong Kong (China)
Pages
211 - 214
DOI
10.5162/Ultrasonic2025/C6-b3
ISBN
978-3-910600-08-9
Price
free

Abstract

Conventional phased arrays are typically used to steer the main lobe under spatial Nyquist constraints. When these constraints are violated, grating lobes emerge. However, in Lamb-wave-based damage identification, side and grating lobes are often overlooked. To address this, a holo-array is proposed in this study. Instead of relying solely on phase control, the phase, frequency, and amplitude of the probe wave are individually tailored for each array element to steer the main lobe, suppress grating lobes, and reduce side lobes. The effectiveness is validated through experiments on an aluminum plate.