P1.8 - Comparison of Two Methods for Determining the Position of Reflection Points Using Ultrasound Echolocation in a Specular Environment

Event
SENSOR+TEST Conferences 2009
2009-05-26 - 2009-05-28
Congress Center Nürnberg
Band
Proceedings SENSOR 2009, Volume II
Chapter
P1 - Mechanical Sensors
Author(s)
G. Kaniak, H. Schweinzer - Vienna University of Technology, Vienna, Austria
Pages
259 - 264
DOI
10.5162/sensor09/v2/p1.8
ISBN
978-3-9810993-5-5
Price
free

Abstract

With the final goal of three dimensional scene analysis by ultrasound echolocation, two approaches are discussed for determining the position of reflection points on specular objects. The first approach uses time-of-flight information at four receivers for the estimation of distance and direction. The second one is based on determining the angle of transmission by evaluating the directional characteristic of the signal pattern. Finally both methods are compared.

Download