P1AP.20 - Improving Detection Chlorine by Field Effect Gas Sensor with Using Temperature Pulse Mode.

Event
17th International Meeting on Chemical Sensors - IMCS 2018
2018-07-15 - 2018-07-19
Vienna, Austria
Chapter
P-1 - Applications of Chemical Sensors
Author(s)
N. Samotaev, A. Litvinov, M. Etrekova - National Research Nuclear University MEPHI, Moscow (Russia)
Pages
474 - 475
DOI
10.5162/IMCS2018/P1AP.20
ISBN
978-3-9816876-9-9
Price
free

Abstract

The gas analytical system for chlorine gas measurement based on metal-insulator-semiconductor field effect (MIS FE) type sensor has been developed. High sensitivity of MIS FE sensor to chlorine allows measuring concentrations in the sub-ppb level and to be stable for overload hydrogen gas concentration typically present in industrial electrolysis application. With the pulse heating mode, the response and relaxation times of the MIS sensor are reduced by an order of magnitude which gives chance to use one for high precision environmental control.