| EUROSENSORS XXXVII |
TP11 - Direct-printed amiodarone electrochemical sensor. Identi-fication of DNA based bioreceptor |
M. Urbanowicz, A. Paziewska-Nowak, K. Bobrowska, A. Sołdatowska, M. Dawgul, D. G. Pijanowska - Polish Academy of Sciences, Warsaw (Poland) |
| EUROSENSORS XXXVII |
TP12 - Sensitive cell identification in impedance flow cytometry using optimized dielectric buffer properties and low cost microchannels |
M. Favrod-Coune, O. Guenat - University of Bern, Bern (Switzerland), P. Eberle - Lucerne University of Applied Sciences, Lucerne (Switzerland) |
| EUROSENSORS XXXVII |
TP13 - Lens-free Microscope for Portable Pollen Grains Imaging System |
A. B. Dharmawan, G. Schöttler, A. Waag, J. D. Prades - Technische Universität Braunschweig, Braunschweig (Germany) |
| EUROSENSORS XXXVII |
TP14 - Recent Advances in Multiparameter 2D Chemical Imaging of Environmental Samples with Optical Sensors (Optodes) |
A. V. Kalinichev, M. R. Rasmussen, K. Koren - Aarhus University, Aarhus (Denmark) |
| EUROSENSORS XXXVII |
TP15 - Fabrication of modified á-Fe2O3 NPs on ZnO NRs/Ni-foam nanocomposite as electrode for electrochemical detection of arsenic in drinking water |
S. Ngok, R. Yann, X. Liu, M. Willander, O. Nur - Linköping University, Norrköping (Sweden), C. O. Chey - Royal University of Phnom Penh, Phnom Penh (Cambodia) |
| EUROSENSORS XXXVII |
TP16 - Influences on the Sensitivity of Camera-Based Colorimetric Gas Sensors Systems |
S. Hoffmann - Fraunhofer EMFT, Munich (Germany), S. Trupp - Bundeswehr University Munich, Neubiberg (Germany) |
| EUROSENSORS XXXVII |
TP17 - Noble Metal Decorated Graphene Sensor for Detecting Hydrogen at Room Temperature |
P. K. Kannan, J. W. Gardner - University of Warwick, Coventry (United Kingdom), M. Tyler - Paragraf Ltd, Somersham (United Kingdom) |
| EUROSENSORS XXXVII |
TP18 - Al-doped ZnO Gas Sensors Toward Safe and Effective Monitoring in Protected Environments |
E. Tavaglione, A. Rossi, V. Guidi, B. Fabbri - University of Ferrara, Ferrara (Italy), M. Ferroni - Institute for Microelectronics and Microsystems IMM-CNR, Bologna (Italy) |
| EUROSENSORS XXXVII |
TP19 - Field Calibration Strategies for Methane Monitoring with Electronic Noses |
G. Domènech-Gil, K. Munnuru Singamshetty, D. Bastviken - Linköping University, Linköping (Sweden), D. Montecinos - Swedish Meteorological, Hydrological Institute SMHI (Sweden) |
| EUROSENSORS XXXVII |
TP20 - Rapid detection of olive oil markers using a gas chromatography sensor system |
O. T. Penagos Carrascal, M. Czerny, T. Sauerwald, G. Zeh - Fraunhofer Institute for Process Engineering and Packaging IVV. Freising (Germany), J. Bröckelmann, M. Bücking - Fraunhofer Institute for Molecular Biology and Applied Ecology IME. Schmallenberg (Germany) |