B5.2 Simultaneous Quality and Flow Rate Monitoring of Diesel Exhaust Fluid by Using A Platinum Thin Film Sensor

Event
SMSI 2021
2021-05-03 - 2021-05-06
digital
Band
SMSI 2021 - Sensors and Instrumentation
Chapter
B5 Chemosensor Applications
Author(s)
R. Bernhardsgrütter, C. Hepp - Innovative Sensor Technology IST AG, Ebnat-Kappel (Switzerland), J. Wöllenstein - University of Freiburg, Freiburg (Germany), K. Schmitt - Fraunhofer Institute IPM, Freiburg (Germany)
Pages
133 - 134
DOI
10.5162/SMSI2021/B5.2
ISBN
978-3-9819376-4-0
Price
free

Abstract

The monitoring of the quality and the flow rate of the diesel exhaust fluid is essential for an efficient selective catalytic reduction in diesel combustion. This article presents a platinum thin film sensor using a combination of the constant temperature anemometry and the 3ω-method to measure continuously the urea content and the flow rate with compensated fluid dependence. The urea content can be determined within 3 % by weight and the flow rate within 4 % full scale. The presented method allows continuous monitoring of two main parameter in the selective catalytic reduction.

Download