P8.6 - A New Mathematical Procedure for Simultaneous Analysis of Gases with Resistive Gas Sensors

Event
AMA Conferences 2015
2015-05-19 - 2015-05-21
Nürnberg, Germany
Band
Proceedings SENSOR 2015
Chapter
P8 - Gas
Author(s)
R. Seifert, H. Keller - Karlsruhe Institute of Technology (KIT), Eggenstein-Leopoldshafen (Germany)
Pages
845 - 847
DOI
10.5162/sensor2015/P8.6
ISBN
978-3-9813484-8-4
Price
free

Abstract

In many applications a multitude of different gases may occur which have to be identified and analyzed simultaneously, for example in detecting cable fire in a cable slot at a very early point of time but with high discrimination to other gases. But well introduced calibration and evaluation procedures are only designed to analyze only one gas or gas mixture. A new and efficient mathematical procedure called SimSens was developed to overcome this drawback. A short outline of SimSens and the validation with real data of four gases and one gas mixture is presented and the ability of simultaneous gas identification and reliability respective accuracy of analysis is discussed.