3.1.5 - Comparison of Self-Heating and Electrode Heating recoveries in a suspended-CNT CNFET NO2 Sensor
- Event
- EUROSENSORS 2026
2026-09-06 - 2026-09-09
Zurich - Band
- Lectures
- Chapter
- Chemical Sensors
- Author(s)
- I. Kraiem, D. Wolf, M. Haluška, C. I. Roman, C. Gentili, C. Hierold - ETH Zürich,Zürich (Switzerland)
- Pages
- 110 - 111
- DOI
- 10.5162/eurosensors2026/3.1.5
- ISBN
- 978-3-910600-12-6
- Price
- free
Abstract
We compare self-heating (SH) and electrode-heating (EH) recovery of a carbon nanotube FET NO 2 sensor. Both methods sustained reproducible sensing across nine cycles, five cycles with EH and four cycles with SH; the post-reset operating point had comparable cycle-to-cycle spread for both methods, while EH delivered a 1.7–2.2× smaller standard deviation in NO ₂ response amplitude.